ZY-JH Polymer Mortar
ZY-JH Polymer Mortar is a two-component cement-based composite material modified with polymer emulsion, primarily composed of cement, polymer emulsion, mineral admixtures, crack-resistant fibers, cement superplasticizer, aggregates, and more. It meets the technical requirements for polymer-modified cement mortar as specified in GB 50728 "Technical Specification for Safety Assessment of Engineering Structural Reinforcement Materials," GB 50367 "Code for Design of Concrete Structure Strengthening," and JTG/T J22 "Code for Design of Highway Bridge Strengthening."
Category:
Polymer-modified cement-based materials
Product accessories:
Contact us
Product Description
Product Introduction
ZY-JH Polymer Mortar is a two-component cement-based composite material modified with polymer emulsion, primarily composed of cement, polymer emulsion, mineral admixtures, crack-resistant fibers, cement superplasticizer, aggregates, and more. It meets the technical requirements for polymer-modified cement mortar as specified in GB 50728 "Technical Specification for Safety Assessment of Engineering Structural Reinforcement Materials," GB 50367 "Code for Design of Concrete Structure Strengthening," and JTG/T J22 "Code for Design of Highway Bridge Strengthening."
Product Advantages
1. High strength, ultra-strong adhesion;
2. Non-shrinking and crack-resistant;
3. High durability, impermeable waterproofing, rust and corrosion resistance, and carbonation resistance;
4. Two product models are available—either for surface application or for grouting;
5. Easy to use—simply mix the two components according to the recommended ratio.
Parameter indicators
| Trial Project |
First-Level Mortar Technical Requirements |
Test Results |
||
| Appearance |
Agent A (powdered material) |
Even, without clumps |
Even, without clumps |
|
| B Agent (Emulsion) |
Uniform, no sediment |
Uniform, no sediment |
||
| Compressive strength, MPa |
7 d |
40 |
52 |
|
| 28 d |
≥55 |
68 |
||
| Flexural strength, MPa |
28 d |
≥12 |
15 |
|
| Shear strength standard value for bonding with steel wire rope, MPa |
≥9 |
18 |
||
| Splitting tensile strength, MPa |
≥7 |
11 |
||
| With concrete direct tensile bond strength, MPa |
≥2.5 and cohesive failure within the concrete |
3.2 and Cohesive Failure in C40 Concrete |
||
| Moisture and Heat Aging Resistance (Strength Reduction Rate, %) |
≤10 |
0.5 |
||
Applicable Conditions
Reinforcement construction using (prestressed) steel wire mesh in projects such as bridges, roads, hydraulic structures, railways, and building construction; surface patching of concrete defects including erosion, spalling, exposed reinforcement, and honeycombing; concrete carbonation prevention and corrosion-resistant repairs; rust-inhibiting and anti-corrosion treatments for steel plate surfaces; and carbon fiber-based surface protection.
Next
Next
Do you have any questions?
Leave your information